ÿþSPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
PETROL X
TOYOTA PREVIA 02 ’! DIESEL
’!
MAKE MOD. YEAR
ALARM/SIREN Position the compact alarms and the sirens on the bulkhead that divides the
passenger compartment and the engine compartment.
POSITION
Position the modular system and the modules under the dashboard, passenger s
CENTRAL UNIT POSITION
side.
POWER SUPPLY + 30: connect to the 4 mm2 RED/WHITE wire in a multiway connector in the fuse
box.
- 31: connect to one of the ground terminal locted behind the left lateral bulkhead,
driver s side.
IGNITION WIRE + 15/54: connect to the wire at the position marked +15/54 located in the wiring
harness coming out of the connector of the ignition key.
DIRECTION INDICATOR Connect to the GREEN/BLACK wire with SILVER reference and to the
GREEN/YELLOW wire with SILVER reference located in a 24 way connector
under the steering column.
ELECTRIC WINDOWS Negative control signal
Front window, driver s side:
cut the RED/BLUE wire with silver references.
Front window, passenger s side:
cut the RED/YELLOW wire with SILVER references..
CENTRAL DOORS LOCKING Negative control signal
Connect to the BLUE wire (unlock) and to the BLUE/WHITE wire (lock) located in
the wiring harness coming out of the central door locking unit placed on the right
of the steering column.
IMMOBILISATION POINT Fuel pump
Cut the BLACK/RED wire located in the wiring harness coming out of the white
connector of the fuel pump.
STARTER +50: cut the wire, at the position marked +50 , in the wiring harness coming out
of the connector of the ignition key.
BONNET SWITCH Install an additional switch on the headlamp support plate, driver s side.
DOORS SWITCH Connect to the RED/ORANGE wire with BROWN references located near the
safety belt winder.
BOOT SWITCH Connect to the RED/BLACK wire with GREY references directly to the original
line.